Agilia SP TIVA – Fresenius Kabi – Syringe Pump – TCI Infusion Modes, DPS, Infusion control
3 sold in last 16 hours
Brand:
Fresenius Kabi

Download : Fresenius Kabi – Agilia-SP-TIVA-brochure
- Dose rate programming : Less risk of errors in prescription computation​
- TCI Infusion mode
- Wide flow rate ranging from 0.1-1200 mL/h & accuracy of ±3 %
- Adaptable to all protocols
- Stand alone or rack mounted
- 2 pressure modes & Dynamic Pressure System (DPS)
- End infusion (V/T & VL) : KVO: adjustable from 0.1 to 5 mL/h, continuous infusion or stop.
- Priming : 3 modes: mandatory, not mandatory, or advised / Rate: 1200 mL/h.
- Induction dose : Dose / time: 0.1 – 99.9 units / 1 second – 24 hours
rate auto-calculation.
- Delivery & Return
RETURN, REFUND & EXCHANGE POLICY
Thank you for shopping at wellwings. We value your satisfaction and strive to provide you with top-quality products. If, for any reason, you are not completely satisfied with your purchase, we are here to assist you with our refund policy. As we strive to ensure the utmost customer satisfaction with our healthcare products. We understand that occasionally, you may need to return or exchange an item, and we are committed to providing a hassle-free return process. Please read our return policy carefully to understand the guidelines and procedures for returning or exchanging products purchased from wellwings.Eligibility for Returns/Exchanges:
- We accept returns or exchanges within 7 days from the date of item delivered.- The item must be unused, undamaged, and in its original packaging with all accessories and documentation included, and in the same condition as when you received it.- Customized or personalized items are not eligible for return or exchange, unless there is a manufacturing defect or damage during transit. Non-returnable items include all consumables & Disposables.Return/Exchange Process:
-To initiate a return and request a refund, please contact our customer service team within the specified timeframe, Return Request can be initiated on website, app, WhatsApp or email.-Provide the order details, order email ID, item description and reason for the return.-Our customer service team will guide you through the return process and provide you with a Return Merchandise Authorization (RMA) number and will be send in your email ID or WhatsApp number, if applicable.-Please securely package the item, including all accessories and documentation, and clearly mark the RMA number if given by our team on the package for efficient processing.-Ship the item back to our designated return address using a traceable shipping method, and retain the tracking information for reference.-The customer team will contact you if some issues are there during tracing of the returned goods.Refunds process
- Once we receive and inspect the returned item, we will notify you of the status of your refund.- If the item meets the eligibility criteria, we will process the refund within 7 - 10 working days- Refunds will be issued in the original form of payment used for the purchase or in some cases through UPI / customer referred Bank accounts if the original payment method is facing issues while transaction.- Please note that shipping and handling charges are non-refundable unless the return is due to our error.Timeframe for Refunds:
- The time required to process a refund may vary depending on the payment method and financial institution involved.- Please allow 7-10 business days for the refund to be credited to your account or appear on your statement.Damaged or Defective Items:
- If you receive a damaged or defective item, please contact our customer service team immediately on our website, app, WhatsApp or e-mail supporting system with detailed information and photographic evidence of the issue.- We will arrange for a replacement or provide further instructions for returning the item, depending on the specific situation.Exchanges:
- Unfortunately, we do not offer direct exchanges. If you wish to exchange an item for a different size, color, or model, please follow the return process outlined above and place a new order for the desired item.- After receiving the returned item and verifying its eligibility, we will process the exchange and ship the new item to you- In case the requested item is out of stock, we will offer you a refund within 7 business days, If in some cases whether delay is happened in refund process the customer will be notified in the delayed period.Return Shipping:
- For eligible returns or exchanges due to manufacturing defects, damage during transit, or errors Wellwings will cover the return shipping cost.- If the return is due to personal preference or non-defective reasons, you will be responsible for the return shipping costs and will be reduced from the refunded amount.Cancellations
- If you need to cancel an order, please contact our customer support team as soon as possible. We will do our best to accommodate your request, provided the order has not been shipped.- If the order has already been shipped, you may follow the return process outlined above.Exceptions and Special Cases:
- In certain circumstances, exceptions to our refund policy may be considered at our discretion.
- We reserve the right to update or modify our refund policy at any time without prior notice. However, any changes will not affect purchases made prior to the policy update.
Contact Us
- If you have any questions or need further assistance regarding our return policy, please don't hesitate to contact our customer support team.- You can reach us through our website, App, WhatsApp, email or phone support system and or by visiting our registered office in Mumbai, Maharashtra.Note: Â This return policy applies to purchases made directly from Wellwings.We appreciate your trust in Wellwings. Our commitment is to deliver the highest quality products and provide exceptional service to meet your healthcare equipment needs. Feel free to contact us for any inquiries or support.If you have any questions or require further assistance regarding our refund policy, please don't hesitate to contact our customer service team. We are here to ensure your satisfaction and provide a seamless shopping experience. - Ask a Question
Estimated Delivery: Mon, Apr 14 – Mon, Apr 21 (Excl Sun)
... people are viewing this right now
- Flow rate range: 0.1-1200 ml/h (depending on the syringe capacity).
- Flow rate accuracy: ± 1% on mechanism ; ± 2 % on syringes.
- Syringe capacities: 5,10, 20, 30/35, 50/60 CC.
- Infusion modes
ml/h. - Dose rate.
- Dose units: ng, μg, mg, cal, kcal, U, kU, mmol, mol, Kmol / kg.
- Time units: 24h / h / min.
- Dilution setting: X units / ml or X units / Y ml.
- Volume or dose / time: 0.1-99.9 units ; 00h01- 96h00.
- Volume limit: 0.1-999.9 ml.
- TCI Functions: Injectomat® TIVA Agilia is an IV anaesthesia system incorporating pharmacokinetics models for Propofol, Remifentanil, Sufentanil in plasma or effect mode.
- Bolus: Manual bolus: Rate: 50 -1200 ml/h; 50 ml/h increment. Programmed bolus (dose or volume/time): 0.1-99.9 units / 0.1-1200 ml/time auto-calculation.
- Programming modes: No drug names: infusion without any display of the drug names. Drug labelling: infusion with the drug names. Vigilant® Drug\\\’Lib: the secured IV Administration mode with a drug library.
- Drug labelling: Display of the drug name based on a list of 50 pre-set drug names.
- Drug libraries: Drug parameters, infusion, bolus and loading dose parameters, authorised infusion modes, infusion mode per default. Inititial drug library of 50 drugs adjustable with Vigilant®, the IV Medication Safety Solution. Up to 120 drugs (depending on comment size) storable in 4 different drug libraries.
- Pressure modes: 2 modes available: variable or 3 pre-set levels – From 100 to 900 mmHg, 50 mmHg increment.
- DPS The Dynamic Pressure System – DPS – warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
- Anti-bolus system: Reduces significantly bolus after occlusion release (0.2 ml max).
Brand | Fresenius Kabi |
Volume Limit | 0.1 - 999 mL |
Priming | 3 modes: mandatory, not mandatory, or advised / Rate: 1200 mL/h. |
Direct Bolus Rate | : 50 - 1200 mL/h (50 mL/h increment). |
Programmed bolus (dose or volume / time) | : 0.1 - 99.9 mL 0.1 - 9999 units / 1 second - 24 h. |
End infusion (V/T & VL) | KVO: adjustable from 0.1 to 5 mL/h, continuous infusion or stop |
Dose Time | 0.1 - 99.9 units / 1 second - 24 hours |
Volume or Dose / Time | 0.1 - 99.9 mL; 00 h 01 - 96 h 00. |
Type of Syringe | Up to 100 types. |
Model Name | Agilia SP TIVA |
Flow Rate Range | 0.1-1200 mL/h |
Flow Rate Accuracy | +/-1% on mechanism : +/- 2 % on syringes. |
Dilution Setting | units / mL or -- units / -- mL. |
Syringes Capacities | 5, 10, 20, 30/35, 50/60 CC. |
In the box | 1. Syringe pump |
---|
0.00
0 reviews
5 | 0 | |
4 | 0 | |
3 | 0 | |
2 | 0 | |
1 | 0 |
Thank you!
Your review has been submitted
Be the first to review “Agilia SP TIVA – Fresenius Kabi – Syringe Pump – TCI Infusion Modes, DPS, Infusion control” Cancel reply
Categories: Medicine Pumps, Syringe Pumps
Tags: Anti Bolus, DPS, Syringe Pump, TCI modes
Brand: Fresenius Kabi
Related Products
Brand: Akas
Infu 5005 – Akas – Infusion Pump – High flowrate pump Download : Akas – Infu 5005 – BrochureÂ
- Bolus function : Auto bolus , Purge bolus
- Target volume & target time setting with auto calculation
- Rotatable clamp for mobile pole/rail
- Connectivity : Upgradable to WiFi interface
- Compatibility : Programmable and compatible to any IV tubing
- Alarm range : Alarm with adjustable 3 levels, audible and visible at 80° viewing angle
- Free flow protection with lever operation
- Less flow alarm generated due to occlusion
- Accuracy : +- 5% , +- 3% on all IV sets
Brand: Vygon
Easymoov 6 – Vygon – Feeding Pump – Safe nutrition mode enteral feeding pump Download – Vygon – Easymoov 6 -Brochure_
- Lightweight and compact, meeting the requirements for ambulatory use, but also suitable for stationary use with a pole clamp accessory
- Battery : Powered by a NiMH (Nickel Metal Hydride) 7.2V 2Ah rechargeable battery, with 20 hours of battery life at 125 ml/h flow rate
- LCD screen and 6 front panel keys for intuitive operation
- Volumetric, continuous flow, rotary peristaltic pump design for enteral feeding
- Flow rate range : 1 to 400 ml/h, with 1 ml/h increments and +/- 5% accuracy
- Automatic tube priming : 600 ml/h for 1 minute 45 seconds
- Occlusion pressure : 0.9 bar +/- 0.2 bar
- Volume range :Â 1 to 9,999 ml, with 1 ml increments
- Feeding setting memory capacity of 24 hours
Brand: Vygon
Easylit 6 – Vygon – Feeding Pump – Continuous rotary peristaltic movement pump Download – Vygon – Easylit 6 – BrochureÂ
- Feeding mode : Volumetric, continuous flow, rotary peristaltic pump for enteral feeding.
- Flow rate : Continuous rotary peristaltic system
- Flow rate range : From 1 to 600 ml/h
- Increments: 1 ml/h
- Accuracy: +/-10 % with tubing for easy lit pump
- Purge: Automatic tube filling at 600 ml/h for 1 min. 35 sec.
- Occlusion pressure: 1+/- 0.2 Bar
- Maximum volume: 1 to 9,999 ml
- Increments: 1 ml.
- Feeding setting memory capacity : 24 h.
- Battery life : 7 hours at 125 ml/h (fully charged battery) with charging time of 7 hrs
Brand: Fresenius Kabi
Amika+ – Fresenius Kabi – Advanced Enteral Feeding Pump Download – Fresenius Kabi – Amika + – BrochureÂ
- Flow Rate Range : 1 – 100 mL/h (1 mL/h increments) ; 100 – 600 mL/h (5 mL/h increments)
- Flow Rate Accuracy : ± 7% at 50 mL/h
- Feeding Mode: Continuous and Bolus mode
- Priming : Automatic, semi-automatic and manual priming available
- Counter : feeding volume counter from 0.001 L to 99.999 L
- Data Events Log : Feeding history: 250 events ; Alarm history: 250 events
- Night Mode to decrease screen brightness
- Keypad Lock to prevent unintentional key presses
- Setting Lock with access code to prevent patient from changing settings
Brand: Technocare Medisystems
TM1509E – Technocare Medisystems – Syringe Pump – High precision control - Syringe Size: The pump supports syringe sizes ranging from 0.2 to 60 mL.
- Accuracy: The pump ensures an accuracy of +2% for precise dosing.
- Number of Syringes: It can handle a single syringe at a time.
- Weight: The device weighs approximately 3 kilograms.
- Display Type: The pump features a digital display with a touch screen interface for easy operation.
- Power Source: It operates on AC power with a voltage range of 100-240V and a frequency of 50/60Hz.
Brand: B'Braun
Infusomat Compact Plus – Infusion Pump – B’Braun – Integrated doseguard Download : B’Braun – Infusomat Compact Plus – Brochure Â
- Display type : High resolution color display with visibility from all angles
- Drug library : Color coded drug library with 3000 drugs of all parameters.
- Intuitive user interface due to self explanatory menu
- Integrated power supply for use with standard power cords
- Integrated pole clamp and handle
- Easy to use disposables with color coded connectors
- Battery type : Extended battery life with highly reliable Lithium-Ion batterie with recharging time approx 3hrs
- Water resistant : Protection against fluid ingress IP34
Benefusion uVP – Mindray – Infusion Pump – BolusGuard Technology Read more
Download – Mindray – BeneFusion uVP – BrochureÂ
- Flow rate range of 1.0 ml/h – 2000 ml/h with high accuracy of ± 4.5%
- Compatibility : Accepts any universal infusion set
- Anti-free flow clamp that automatically engages when the door is opened
- Infusion modes : Rate mode, Dose Mode, Time mode, Dose Time
Mode, Sequential Mode, Intermittent Mode, Loading Dose Mode, Ramp Mode, Micro infusion Mode, Drip Mode, Rhythm Dose - Large color 3.5″ LCD touchscreen display with intuitive user interface
- Advanced safety features like occlusion detection, in-line air detection and low battery alarm
- History log : Upto 5000 events that records infusion data for tracking and documentation
- Multifunctional connector (optional) : RS232, nurse call connector, DC adapter, etc. Integration Connect with BeneVision Central Monitoring ,System (CMS), Connect with BeneFusion nCS infusion central station , Support HL7 protocol
Brand: Technocare Medisystems
TM 609 – Technocare Medisystems – Syringe Pump – High Adaptability pump - No Pulse Delivery: The pump provides a full uniform motion, ensuring smooth pulseless delivery.
- No Cleaning Required: The pump does not require cleaning after use, making it convenient for healthcare professionals.
- Transport Different Characteristics: The pump can handle different fluid characteristics by simply replacing the syringe.
- Flow Rate Range: From 0.1 ml/h to 1500 ml/h.
- KVO (Keep Vein Open) Rate: 1 ml/h.
Brand: Niscomed
SP-08 – Niscomed – Syringe Pump – Accurate delivery system - Accuracy: No more than ± 2%
- Battery working time: Not less than 8h
- KVO speed range: 2.5ml/h
- Dimensions: 248 x 151.5 x 97mm
- Injection time setting range: 1min – 99:59min
- Working Environment: Temperature 5-40°C, relative humidity <80%.
- Operating Mode: Speed infusion mode, speed + time infusion mode, speed + volume infusion mode.
- Precise Delivery: The syringe pump ensures accurate delivery of fluids, making it suitable for various medical applications.
- Programmable: The device allows for programmable settings, enabling customization for specific infusion protocols.
Brand: Byond
BYS 820 – Byond – Infusion Pump – Precise rate control, Multiple modes pump Download : Byond – BYS 820 – Brochure
- Rate Control: Allow precise control of the flow rate of fluids or medications being delivered. This is important for ensuring accurate and consistent dosing.
- Multiple Modes: ml/h and drop/min with Purge function
- Compatibility: Compatible with any brands of infusion sets after correct calibration.
- Alarms and Alerts: Alarms and alerts to notify healthcare providers of any issues, such as occlusion, empty, low battery, end of infusion, door open, wrong setting.
- Programming Options: Three levels of occlusion: high, middle and low.
- KVO (keep-vein-open) automatically opens as infusion is completed, KVO rate is 1-5ml/h(1ml/h step).
- Battery Operation: Built-in battery or an option for battery operation to ensure continued operation during power outages.
- User-Friendly Interface: HD LCD Display with large fonts and friendly user interface.
Brand: Fresenius Kabi
Syringe Pump – Fresenius Kabi – Injectomat TIVA Agilia – TCI, DPS, ABS - TCI Functions: Injectomat® TIVA Agilia is an IV anaesthesia system incorporating pharmacokinetics models for Propofol, Remifentanil, Sufentanil in plasma or effect mode.
- Drug libraries: Drug parameters, infusion, bolus and loading dose parameters, authorized infusion modes, infusion mode per default. Inititial drug library of 50 drugs adjustable with Vigilant®, the IV Medication Safety Solution. Up to 120 drugs (depending on comment size) storable in 4 different drug libraries.
- Pressure modes: 2 modes available: variable or 3 pre-set levels – From 100 to 900 mmHg, 50 mmHg increment.
- DPS The Dynamic Pressure System – DPS – warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
- Anti-bolus system: Reduces significantly bolus after occlusion release (0.2 ml max)
Brand: BPL
Acura S1 – BPL – Syringe Pump – Dual display Download BPL Acura-S1 – Brochure
- Dual Display: 2.8-inch color LCD & LED for rate display
- Compatible with all standard syringes: 5ml – 60ml
- Infusion Modes: Rate Mode, Time Mode and Drug/Weight Mode
- In-built Drug Library
- Dual Bolus Modes: Manual & Automatic bolus
- 3 level occlusion sensitivities setting (programmable)
- 2000 history records and last configuration memory
- Horizontal & Vertical fixation clamp
Reviews
There are no reviews yet.