- Single-channel ECG recorder
- Supports automatic and manual modes of recording
- Thermal print ensures high-resolution ECG printing on 50 mm paper
- Stores last ECG recording in the memory
- Built-in rechargeable NiMh battery
- Delivery & Return
RETURN, REFUND & EXCHANGE POLICY
Thank you for shopping at wellwings. We value your satisfaction and strive to provide you with top-quality products. If, for any reason, you are not completely satisfied with your purchase, we are here to assist you with our refund policy. As we strive to ensure the utmost customer satisfaction with our healthcare products. We understand that occasionally, you may need to return or exchange an item, and we are committed to providing a hassle-free return process. Please read our return policy carefully to understand the guidelines and procedures for returning or exchanging products purchased from wellwings.Eligibility for Returns/Exchanges:
- We accept returns or exchanges within 7 days from the date of item delivered. - The item must be unused, undamaged, and in its original packaging with all accessories and documentation included, and in the same condition as when you received it. - Customized or personalized items are not eligible for return or exchange, unless there is a manufacturing defect or damage during transit. Non-returnable items include all consumables & Disposables.Return/Exchange Process:
-To initiate a return and request a refund, please contact our customer service team within the specified timeframe, Return Request can be initiated on website, app, WhatsApp or email. -Provide the order details, order email ID, item description and reason for the return. -Our customer service team will guide you through the return process and provide you with a Return Merchandise Authorization (RMA) number and will be send in your email ID or WhatsApp number, if applicable. -Please securely package the item, including all accessories and documentation, and clearly mark the RMA number if given by our team on the package for efficient processing. -Ship the item back to our designated return address using a traceable shipping method, and retain the tracking information for reference. -The customer team will contact you if some issues are there during tracing of the returned goods.Refunds process
- Once we receive and inspect the returned item, we will notify you of the status of your refund. - If the item meets the eligibility criteria, we will process the refund within 7 - 10 working days - Refunds will be issued in the original form of payment used for the purchase or in some cases through UPI / customer referred Bank accounts if the original payment method is facing issues while transaction. - Please note that shipping and handling charges are non-refundable unless the return is due to our error.Timeframe for Refunds:
- The time required to process a refund may vary depending on the payment method and financial institution involved. - Please allow 7-10 business days for the refund to be credited to your account or appear on your statement.Damaged or Defective Items:
- If you receive a damaged or defective item, please contact our customer service team immediately on our website, app, WhatsApp or e-mail supporting system with detailed information and photographic evidence of the issue. - We will arrange for a replacement or provide further instructions for returning the item, depending on the specific situation.Exchanges:
- Unfortunately, we do not offer direct exchanges. If you wish to exchange an item for a different size, color, or model, please follow the return process outlined above and place a new order for the desired item. - After receiving the returned item and verifying its eligibility, we will process the exchange and ship the new item to you - In case the requested item is out of stock, we will offer you a refund within 7 business days, If in some cases whether delay is happened in refund process the customer will be notified in the delayed period.Return Shipping:
- For eligible returns or exchanges due to manufacturing defects, damage during transit, or errors Wellwings will cover the return shipping cost. - If the return is due to personal preference or non-defective reasons, you will be responsible for the return shipping costs and will be reduced from the refunded amount.Cancellations
- If you need to cancel an order, please contact our customer support team as soon as possible. We will do our best to accommodate your request, provided the order has not been shipped. - If the order has already been shipped, you may follow the return process outlined above.Exceptions and Special Cases:
- In certain circumstances, exceptions to our refund policy may be considered at our discretion.
- We reserve the right to update or modify our refund policy at any time without prior notice. However, any changes will not affect purchases made prior to the policy update.
Contact Us
- If you have any questions or need further assistance regarding our return policy, please don't hesitate to contact our customer support team. - You can reach us through our website, App, WhatsApp, email or phone support system and or by visiting our registered office in Mumbai, Maharashtra. Note: This return policy applies to purchases made directly from Wellwings. We appreciate your trust in Wellwings. Our commitment is to deliver the highest quality products and provide exceptional service to meet your healthcare equipment needs. Feel free to contact us for any inquiries or support. If you have any questions or require further assistance regarding our refund policy, please don't hesitate to contact our customer service team. We are here to ensure your satisfaction and provide a seamless shopping experience. - Ask a Question
₹28,700.00 Original price was: ₹28,700.00.₹25,999.00Current price is: ₹25,999.00.
The BPL Cardiart 6108T Single-Channel ECG machine is a comprehensive solution for recording, analysing & storing electrocardiograms effectively & efficiently in clinical environments. This dependable and intuitive ECG machine delivers accuracy and precision while ensuring easy data transferability between healthcare facilities or institutions via wired connections.
- Design:
The BPL Cardiart 6108T ECG machine is a compact, single-channel device that can be used for clinical diagnostics and long-term patient monitoring. The device features an ergonomic design, making it easy to transport and use in any medical setting. With a small footprint and lightweight body, you can carry this device comfortably in any lab or clinic environment.
- Advanced Features:
The BPL 6108T ECG machine provides advanced features such as a 12-lead acquisition system with a real-time display of leads on the LED monitor. The device also offers rhythm analysis, including a display of QRS morphology, noise rejection filters, an arrhythmia analyzer, a power supply cord and an external VCR connection.
- Advanced Features:
The BPL ECG machine offers diagnostic capabilities such as simultaneous three/six-channel recording and tracing capability along with the standard 12 lead simultaneous display feature. In addition, this machine can perform ST segment analysis and has printing capabilities through the built-in thermal printer, which allows you to print results quickly for easy record keeping.
- High Performance:
This efficient device boasts superior performance for accurate readings. It includes filters to ensure clean signal transmission and improved signal quality without distortion or interference from noise or motion artifacts. It also provides ample data storage with data management software so you can access essential readings quickly for further review.
- Cost-Effective:
This affordable device makes high-performance cardiac care accessible to everyone. Its convenient design means less maintenance is required, which reduces overhead costs significantly over time. Furthermore, its fast response time helps reduce diagnostic times, which increases efficiency and cost savings while maintaining accuracy and reliability.
The BPL Cardiart 6108T ECG machine price is very economical and is ideal for busy healthcare providers who need reliable cardiac diagnostics solutions. With advanced features and user-friendly operation, this machine ensures accurate readings in every use.
Power supply range | AC 230 V ± 10 |
Power consumption | Less than 12 W |
Battery | Rechargeable NiMH 9.6 V, 1500 mAH battery (Built-in) |
Battery Capacity | 3 Hours in single-channel mode (With a fully charged battery 200 complete ECGs are possible in auto mode with single channel print format) |
Battery charging indicator | Yes |
Battery low indication | Yes |
Recharging time | Approximately 14 Hours for 100 charging |
Mains protection | Fuse: TO.1A |
Internal power supply | Fuse-miniature, 4A, Time-lag, T-Protection |
Battery protection | Polymer resettable fuse |
Operating Temperature | 10 to 40 deg. C |
Relative Humidity | 25 to 90 non-condensing |
Safety Standard | Compliance to Class 11 Type CF , IEC 60601 - 1, IEC 60601 - 2 – 25 |
EMC | IEC 60601 - 1- 2 |
Dimension | 270 (L) x 180 (H) x 60 (D) mm |
Weight | < 1.5 Kgs |
ECG Acquisition | 10 bits; 500 samples / sec |
ECG Leads | Standard 12 leads; Acquired 8 leads; Reconstructed 4 leads (Ill, aVR, aVL, aVF) with a lead indication |
Recording sensitivity | Manual mode: 2.5 - 5 -10 - 20 rnm/rnv ± 5 Auto mode: Dependent on the signal strength Optimises automatically to 2.5 - 5 - 10 - 20mm/mV ± 5 |
Filters | Mains interference / Muscle filter Linear phase digital 50 Hz Notch filter with, linear Phase selectable 25 or 35 Hz - 3 dB response Anti drift filter Digital 0.5Hz Anti Drift High pass linear phase filter always inserted and cannot be switched off |
Signal Memory | 10 Seconds for each lead in Auto mode |
Operating modes | Manual - acquisition and printing in real time Auto - simultaneous acquisition |
Parameter Calculation | Yes, in Auto mode (Selectable) |
Keyboard | Tactile keypad with 9 function keys and 25 LED function indicators |
Input Dynamics | ± 300 mV @ 0 Hz; ± 5 mV in the pass band |
Input Impedance | > 100 Mohms |
Frequency Response | 0.5 Hz to 150 Hz (- 3dB) without Mains / Muscle Filters |
Time constant | 3.2 seconds |
CMRR | 90 dB@50 Hz |
DF Protection | Internal |
Recording system | Thermal printer, 8 dots / mm; 48 mm usable print width |
Thermal Paper | In rolls: Height 50 mm, Length 20 m, gridded |
Print channel | 1 |
Paper transport speed | 25 or 50 mm / sec |
- Warranty: 1 year
In the box | – Patient cable- 1 no |
---|
5 |
|
0 |
4 |
|
0 |
3 |
|
0 |
2 |
|
0 |
1 |
|
0 |
Thank you!
Your review has been submittedRelated Products
Download – BPL Cardiart 9108 – Brochure
- 12-channel ECG recording
- 5.7-inch foldable LCD display
- Automatic parameter measurement and interpretation
- 24-bit A/D converter, 0.01 – 300 Hz bandwidth, 16000 Hz sampling frequency
- Internal storage of upto 800 ECGs that can be enlarged by USB
- Built-in rechargeable Li-ion battery
- Report formats: PDF and optional SCP/FDA-XML/DICOM data export
- Connectivity: FTP, supports barcode scanner & USB printer, optional Wi-Fi
- Optional PC interface software allows to access EMR/PACs/GDT-based systems (HL7 protocol)
Download – BPL Cardiart 6208 View ECG machine – Brochure
- Three-channel ECG recording
- 3.5 inch color LCD screen
- Automatic measurement and interpretation
- ≥12-bit A/D converter, 0.05 – 150 Hz bandwidth, 1000 Hz sampling frequency
- Internal storage for up to 500 ECGs that can be enlarged by USB
- High performance Li-ion rechargeable battery
- Report formats: PDF and optional SCP/FDA-XML/DICOM
- Connectivity: FTP, supports barcode scanner & USB Printer
Download – Contec 100G – Brochure
- Large LCD display waveform and data
- The high-resolution thermal printing array system
- Frequency response is as high as 150 Hz
- Capable of printing continuously on channel trace and annotations including lead mark and parameter such as sensitivity, paper
- speed and filter operation status
- High-resolution digital filter inhibits baseline drift without affecting ECG waveform
- Floating input circuit meets IEC safety standard
- Rechargeable battery supporting more than 50 patient examinations
- Internal software: GB, FR, IT, ES, DE, TR
Download – Comen CM1200B – Brochure
- 12-lead simultaneous acquisition and amplification; 12 ECG waveforms recording simultaneously; all-digital and full-floating design
- 5.7 inch single color display (resolution: 320 X 240)
- Supporting multi-language. Chinese, English, Spanish, Polish, etc
- Automatic measurement and interpretation tests are selectable
- Up to 122 kinds of arrhythmia analysis
- Manual/Auto/Rhythm rn working modes
- Different recording modes: recording, printing recording, printing
- Using unique high-precision digital filter to eliminate baseline drift and other disturbances
Download – Cardiart 9108d – Brochure
- 12-channel ECG recording
- 7-inch high-resolution color LCD with touch screen option
- Glasgow ECG Interpretation Algorithm
- 24-bit A/D converter, 0.01 – 300 Hz bandwidth, 16000 Hz sampling frequency
- Internal storage of up to 800 ECGs that can be enlarged by USB & SD card
- High-performance Li-ion rechargeable battery
- Report formats: PDF and optional SCP/FDA-XML/DICOM data export
- Connectivity: FTP, supports barcode scanner & USB printer, optional Wi-Fi
- Optional PC interface software allows to access EMR/PACs/GDT-based Systems (HL7 protocol)
Download – Contec TLC9803 dynamic ECG holter – Brochure
- Real-time store ECG data for 24-hour
- Flexible analysis channel selection function
- One-key print, convenient and fast to print the reports
- Arrhythmia analysis based on MCSSTM and TMCATM
- With analysis functions for 5-minute, 1-hour and 24-hour heart rate variability
- The death risk in patients with myocardial infarction can be predicted by the “HRT” analysis function.
- The risk of sleep breath pause can be predicted by the unique “Sleep breath pause syndrome “analysis function.
- “T-wave alternation” is an important index to predict malignant arrhythmia and sudden cardiac death
- Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
- More than 10 templates (such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
- Powerful pacemaker analysis functions with many pacing analysis templates, such as “Dual chamber pacing”, “Atrial pacing”, “Ventricular pacing”, “Ventricular Pseudofusion” and “Ventricular asynchronous pacing”, etc.
Download – Contec_ecg_300g – Brochure
- 3 channel ECG machine with 12-lead ECG signal processing.
- 3.5″TFT Color LCD
- 12 Leads ECG simultaneous acquisition
- Simultaneous display of 3/6/12 leads ECG waveform
- ECG waveform in AUTO/Manual mode
- Diagnosing ECG waveform parameters automatically with self interpretation
- “Lead off” and “Lack of paper” alarms
- Patient History Management
Download – Bpl Cardiart Genx3 – Brochure
- Three-channel ECG recording with trace darkness control
- Wide 4.3 inch 65K Color TFT display
- Glasgow ECG Interpretation algorithm
- 12-bit A/D converter, 0.05 – 150 Hz bandwidth, 1000 Hz sampling frequency
- Alphanumeric keypad with soft silicone keys
- Full disclosure view of ECG analysis on display
- Internal storage of upto 250 ECGs that can be enlarged by USB
- Rechargeable Li battery for energy-efficient operation
- Connectivity: supports USB printer, optional FTP, export selected record(s) in HL7 format
Download – ECG CONTEC 1200G – Brochure
- Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
- Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
- Multiply printing modes and formats, including auto 12×1, auto 6×2+1, auto 6×2+1_H, auto 6×2, auto 6x2_H, auto 3×4+1, auto 3×4+2, rhythm 12, rhythm 10, rhythm 8, rhythm 6, manual, etc. Trend chart and histogram of P-R interval can be printed, waveform length printed can be adjusted, and with time print function, which meets different requirements.
- Paper speed: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s.
- With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.(The FDA version of the device has no automatic analysis function, but you can realize it through free PC software))
- Built-in memory stores up to 1000 cases, convenient for case review and statistic.
- Multi-language(Turkish, French, Chinese, English, German, Kazakstan, Polish, Portuguese, Russian, Slovenian, Spanish and Ukrainian) interface and report.
- In optimal DC state, up to 10-hour standby time, continuous print more than 3-hour, record up to 300 ECG waveform(commonly, it is 3s case), which meets the requirements of visiting a patient at home and body examination.
Download – CONTEC ECG 600G – Brochure
- 6 Channels
- Touch Screen
- Self Interpretation
- Adopt high resolution thermal printing system.
- No need for any adjustments.
- Recording frequency: up to 150H.
- Real time and continuously record the clear and accurate ECG waveform.
- Full digital filter design, anti-baseline drift, AC and EMG interference.
- Adjust the baseline automatically.
- Adopt digital signal processing technology and get high quality ECG waveform.
- Functions of auto measurement, auto analysis and auto diagnosis for routine ECG parameters.
- Display of 3/6/12 lead ECG, “Lead off” and “Lack of paper” on one screen.
- Store more than 1000 cases.
- Multi-language interface and report.
Download – Comen CM300 – Brochure
- Accurate and clear ECG waveform
- Working state display
- Economical to save recording paper
- Sync collection for 12-lead ECG, adopt digital signal processing technology and get high-quality ECG waveform via power frequency filter, baseline filter and EMG filter of ECG signal.
- Display of 3/6/12-lead ECG, print mode, sensitivity, paper speed and filter state, etc. on one screen, convenient for contrastively diagnosing.
- Multiple printing modes and formats, including manual, auto 4×3, auto 3×4+1, auto 3×4, auto 2×6+1, auto 2×6, auto 3-2+1, auto 3-2, auto 1×12+1, auto 1×12, rhythm 4, rhythm 3 and rhythm 2, etc. Waveform length printed can be adjusted, and with time print function, which meets different requirements.
- With the functions of auto-analysis and auto-diagnosis for routine ECG parameters, provide measurement results and auto-diagnosis conclusion for HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1), etc. which reduces the doctor’s burden.
- Built-in memory stores up to 1000 cases.
- Multi-language interface and report.
Download – contec ECG Holter monitor – Brochure
- Adopt 12-lead system of international standard, continuously record ECG waveform up to 48-hour.
- Sync analysis for 12-lead, and any channels can be selected as the main analysis channel, which ensures that QRS waveform can be found accurately, and no distortion.
- With more than 10 templates(such as atrial premature beat, ventricular premature beat, long interval, atrial fibrillation, etc.) and many user-defined modules, which can almost distinguish any kind of pathologic waveforms.
- Flexible atrial fibrillation analysis, which ensures that physicians can use the whole or segmented AUTO/manual analysis, more accurate in atrial fibrillation analysis.
- All pacemakers(such as AAI, VVI, DDD etc.) can be analyzed by the powerful pacemaker analysis function.
- Single or full-lead ECG in any time bucket can be reviewed by the fast review analysis function.
- With analysis functions for 5-minute, 1-hour and whole heart rate variability.
- One-key print, convenient and fast to print the reports.
- The death risk in patients with myocardial infarction can be predicted by the “HRT” analysis function.
- “T-Wave alternation” is an important index to predict the malignant arrhythmia and sudden cardiac death.
- With QTD(QT dispersion), VCG(vector cardiogram), VLP(ventricular late potential) and TVCG(time vector cardiogram) analysis modules, more valuable in analysis report.
Reviews
There are no reviews yet.